B2 HVA45TD VLF High Voltage Test Set
The compact, lightweight HVA45TD high voltage tester provides all essential information to determine the condition of medium and high voltage cables. The HVA45TD combines the small and portable VLF test set with an integrated Tan Delta diagnostic unit to meet all international test guides (e.g. IEEE 400.2-2013). Both VFL and DC tests can be performed with B2 Electronics’ HVA45TD, as well as sheath testing with sheath fault location possibilities.
HVA45TD, as well as sheath testing with sheath fault location possibilities.
Rapidly measure and test assets with programmable test sequences with tailor-made software tools, whilst simultaneously download reports to USB flash drive for later analysis and observation, thus eliminating any need for an on-site PC.
The dry-type transformer does not include oil or arching contacts making this test set virtually maintenance free. Designed for continuous operation without any thermal limitations, the HVA45TD can be operated manually or set up for automatic test sequences. The compact size of the VLF high voltage tester allows in-field procedures to run smoothly and efficiently.
ESS Code: HVLF.7
- Pure sinusoidal output voltage (load-independent)
- Leakage Guard® - leakage current correction
- Ultra-light and compact weight (36 kg)
- Protection class IP67 (with closed lid)
- Total protection – almost unbreakable, watertight, dustproof & corrosion proof case
- Large Colour display (4,3”)
- USB and Bluetooth connections
- Cable testing according: IEC60502-2:2015, IEEE 400.2-2004, CENELEC HD 620/621, IEEE400.2-2013 etc.
- Upgradable with partial discharge diagnostic system (optional)
- Two integrated & automatic discharge devices
- Easily exchangeable HV cable
- Intuitive menu operation
- Dimensions: 500 x 305 x 457mm
- Weight: 36kg
Set up an Account
Login or create an account to gain access to your account history and document library. Link your Web Account to your ESS Credit account to hire online, contact us for details.
B2 HVA45TD VLF High Voltage Test Set
hire Price
ESS Code: HVLF.7Rates exclude VAT and Damage Waiver
£623.00 Ex. VAT
Minimum hire period: 5 days
Lead time: 1 day
Please note you will be charged for the minimum hire period if your order is for a period less than this. A web account linked to your ESS Credit account is required to hire online.
Frequently Hired Together
B2 HVA45TD VLF High Voltage Test Set
HVLF.7Baur KSG 200 Cable Identifier
Megger Teleflex SX-1
Total Combined Hire Price
Rates exclude VAT and Damage Waiver
£1,606.00 Ex. VAT
Minimum hire period: 5 days
Please note you will be charged for the minimum hire period if your order is for a period less than this.
Key Product Features
Pure sinusoidal output voltage (load-independent)
Leakage Guard® - leakage current correction
Ultra-light and compact weight (36 kg)
Protection class IP67 (with closed lid)
Open your ESS Account Today
An ESS Credit Account linked to your Web Account is required to hire products online.
Trading with ESS is quick and simple with an ESS account. An ESS Web Account allows you to hire online, access to the MyAccount area and our Technical Document library. Link this to an ESS Credit Account to Hire online and get reporting on your hires in the MyAccount area too.
Already have an ESS Credit Account? You can request we link your web and credit accounts here.