Megger HVB10 Earth Sheath Fault Tester
The Megger HVB10 is a specialist high-voltage bridge device for locating sheath and earth faults in long cables. It offers high resolution, dual-mode operation, and a compact HV connection setup ideal for utilities, power networks, telecoms and industrial clients
The Megger HVB10 Earth Sheath Fault Tester is engineered to deliver accurate and dependable cable sheath fault location even over extended high-voltage cable runs. As high-voltage (HV) bridge technology, it is especially suited to cases where reflection-based approaches fail, such as long crossbonded cables or deep burial scenarios.
This instrument executes an automatic test sequence; you can choose between a standard mode (fast locating of typical sheath faults up to several hundred kilo-ohms) and a high-accuracy mode (for difficult, high-resistive or intermittent faults). The intermittent-fault detection algorithm enables identification even when the fault spark is sporadic.
Because it measures resistance rather than relying solely on impedance reflection, the HVB10 is robust against changes in cable impedance and imperfections in the line. This makes it particularly valuable in long underground, submarine, or crossbonded cable systems. Used in Utility networks applications (electricity distribution, transmission) for diagnosing sheath faults in long HV feeders. Subsea or underground cable installations (offshore wind, offshore substations). Telecommunications and pilot cable systems bundled with power circuits. Heavy industrial sites (mining, petrochemical, water utilities) where long HV interconnect cables exist and Crossbonded cable systems in power plants or large infrastructure projects
ESS Code: HCFL.27
Key features for the Megger HVB10
- High-resolution HV bridge for sheath fault locating
- Dual test modes: standard & high accuracy
- Intermittent fault detection capability
- Single high-voltage connection cable
- Adaptive load charging for faster operations
- Automatic test sequencing (easyGo UI)
- Bi-polar prelocation to eliminate external influence
Set up an Account
Login or create an account to gain access to your account history and document library. Link your Web Account to your ESS Credit account to hire online, contact us for details.
Megger HVB10 Earth Sheath Fault Tester
hire Price
ESS Code: HCFL.27Rates exclude VAT and Damage Waiver
£685.00 Ex. VAT
Minimum hire period: 5 days
Lead time: 1 day
Please note you will be charged for the minimum hire period if your order is for a period less than this. A web account linked to your ESS Credit account is required to hire online.
Frequently Ordered Together
Megger HVB10 Earth Sheath Fault Tester
HCFL.27Baur T811 Single Channel TDR
MIT320 Insulation/Continuity Tester
Combined Hire Price
Rates exclude VAT and Damage Waiver
£841.00 Ex. VAT
Minimum hire period: 5 days
Please note you will be charged for the minimum hire period if your order is for a period less than this.
Key Product Features
Precise high-voltage bridge measurement for sheath (earth) faults
Two operating modes (standard and high accuracy)
Built-in intermittent fault detection and adaptive load charging
Only one high-voltage connection cable (simplified setup)